Fire protection

WICTEC 50FP/60FP Fire protection

WICTEC 50 FP and WICTEC 60 FP fire protection curtain wall provides performance when needed in areas such as stairwells, extensions, hallways and glazed roofs, in accordance with classifications G30 / F30 (DIN) and EI 30 / EI 60 (EN). All architectural concepts of WICTEC 50 and WICTEC 60 can be realised and adapted to provide the necessary fire protection requirements, as well as being seamlessly integrated into standard façades where fire protection is not required.

Technical Specifications

System Technology

  • For vertical and overhead glazing (fire protection up to 0º inclination)
  • Slim sight lines: 50 mm or 60 mm
  • Compatible and structurally identical with WICTEC 50 and WICTEC 60 standard systems
  • Infills: glass or panel
  • Extended freedom in design with large infill dimensions possible
  • Suitable for internal and external applications
  • The WICONA fire protection parapet, in resistance class W90, offers the appropriate solution to prevent
    fire flashover with standard façades.
  • Can also be combined with WICSTYLE 77 FP fire protection doors and WICLINE 75 FP fire protection
    windows

 

Air permeability

Class AE

Water tightness

RE 1200

Resistance to wind load

2000 / –3200, safety 3000 / –4800 Pa

Impact resistance

Class E5 / I5

Approval

German approval: For vertical curtain wall and overhead glazing in accordance with F30 and G30

Quality assurance

Certified according to ISO 9001:2008

Environmental management

Certified according to ISO 14001

System width:

50 mm / 60 mm

Basic system

WICTEC 50 / WICTEC 60

Fire protection classes

G30 / F30 (DIN) EI 30 / EI 60 (EN)

Infill dimensions

Portrait format up to 1800 mm x 3000 mm Landscape format up to 2400 mm x 1400 mm

Heigth of façade

up to 5000 mm

Polygon façade

up to ± 5°

Infill thickness

F30 / G30: up to 38 mm, EI 30 / EI 60: up to 57 mm